Rheem 871026 Instruções de Operação

Consulte online ou descarregue Instruções de Operação para Aquecedores e fervedores de água Rheem 871026. Rheem 871026 Operating instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 76
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
This water heater must be installed and serviced by an authorised person.
Please leave this guide with the householder.
Owner’s Guide
and
Installation Instructions
Electronic Continuous Flow
Gas Water Heater
871, 875 Series
Vista de página 0
1 2 3 4 5 6 ... 75 76

Resumo do Conteúdo

Página 1 - Installation Instructions

This water heater must be installed and serviced by an authorised person. Please leave this guide with the householder. Owner’s Guide and Installation

Página 2

10 TEMPERATURE CONTROL – STANDARD STANDARD CONTROLLER FUNCTIONS If one or more controllers are installed, at least one must be on for

Página 3 - CONTENTS

TEMPERATURE CONTROL – STANDARD 11 STANDARD CONTROLLER integrity Note: water volume button, water volume operating light and water volume symbol are

Página 4 - ABOUT YOUR WATER HEATER

TEMPERATURE CONTROL – STANDARD 12 TEMPERATURE SETTINGS – STANDARD CONTROLLER The temperature settings of each type of controller are: Bathroom1 &

Página 5 - HOW HOT SHOULD THE WATER BE?

TEMPERATURE CONTROL – STANDARD 13 TEMPERATURE ADJUSTMENT – STANDARD CONTROLLER A controller must be on and have priority to be able to adjust the te

Página 6 - GOING ON HOLIDAYS

TEMPERATURE CONTROL – STANDARD 14 KITCHEN CONTROLLER – STANDARD The Kitchen controller allows the user to select the temperature setting for the hot w

Página 7

TEMPERATURE CONTROL – STANDARD 15 To operate the Kitchen controller: 1. Turn off the Bathroom controller(s)  If a temperature setting is displayed

Página 8

TEMPERATURE CONTROL – STANDARD 16 BATHROOM CONTROLLERS – STANDARD The Bathroom controller(s) allows the user to select the temperature setting for the

Página 9 - TEMPERATURE CONTROL

TEMPERATURE CONTROL – STANDARD 17 ch e ck h o t wa t e r te m p er a t u re b e fo r e u se on of f 40 C pr i o rity in u s e 42 C pr i o

Página 10

TEMPERATURE CONTROL – STANDARD 18 WATER VOLUME FUNCTION – STANDARD CONTROLLER The water volume function is designed to warn, by a beeping sound, that

Página 11 - STANDARD CONTROLLER

TEMPERATURE CONTROL – STANDARD 19 5. Turn off the alarm  Press the water volume button to turn off the alarm. The water volume operating light goes

Página 12

PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd or Paloma Industries L

Página 13

20 TEMPERATURE CONTROL – DELUXE DELUXE CONTROLLER FUNCTIONS If one or more Deluxe controllers are installed, at least one must be on or the bath fil

Página 14 - Kitchen Controller

TEMPERATURE CONTROL – DELUXE 21 bath fill water volume display panel – The selected bath fill water volume is displayed in litres on all Deluxe contro

Página 15

TEMPERATURE CONTROL – DELUXE 22 VOICE PROMPT AND OPERATING TONE The Deluxe controllers have a series of voice prompts and operating tones

Página 16 - Bathroom Controller

TEMPERATURE CONTROL – DELUXE 23 Adjusting the Volume of the Voice Prompt and Operating Tone The volume of the voice prompt and the operating tone can

Página 17

TEMPERATURE CONTROL – DELUXE 24 TEMPERATURE SETTINGS – DELUXE CONTROLLERS The temperature settings of each type of Deluxe controller are: Bathroom1

Página 18

TEMPERATURE CONTROL – DELUXE 25 TEMPERATURE ADJUSTMENT – DELUXE CONTROLLERS A controller must be on with the ACTIVE indicator displayed to be able t

Página 19 - 6. Close the hot tap

TEMPERATURE CONTROL – DELUXE 26 KITCHEN CONTROLLER – DELUXE The Kitchen Deluxe controller allows the user to select the temperature setting for the ho

Página 20 - TEMPERATURE CONTROL – DELUXE

TEMPERATURE CONTROL – DELUXE 27 To operate the Kitchen Deluxe controller: 1. Turn off the Bathroom Deluxe controller(s)  If a temperature setting

Página 21 - BATH (l)

TEMPERATURE CONTROL – DELUXE 28 BATHROOM CONTROLLERS – DELUXE The Bathroom Deluxe controller(s) allows the user to select the temperature setting for

Página 22

TEMPERATURE CONTROL – DELUXE 29 To operate a Bathroom Deluxe controller: 1. Turn off the Kitchen Deluxe controller  If a temperature setting is di

Página 23 - ASSISTANCE CALL FUNCTION

3 CONTENTS HOUSEHOLDER - We recommend you read pages 4 to 41. The other pages are intended for the installer but may be of interest. About Your W

Página 24

TEMPERATURE CONTROL – DELUXE 30 BATH FILL MODE The Bath Fill mode is designed to allow the water heater to deliver a selected volume of water at a sel

Página 25

TEMPERATURE CONTROL – DELUXE 31 5. Close the front panel on the Deluxe controller. 6. Turn on the Bath Fill mode  Press the BATH FILL button. On

Página 26 - BATH FILL

TEMPERATURE CONTROL – DELUXE 32 Bath Fill Mode – Explanatory Notes To operate the Bath Fill mode: 1. Turn off all Deluxe controllers  It is advise

Página 27 - 8 8 8 8

TEMPERATURE CONTROL – DELUXE 33 4. Set the bath fill water volume  Press the BATH FILL VOLUME  (up button) or the BATH FILL VOLUME  (down button)

Página 28 - Controller

TEMPERATURE CONTROL – DELUXE 34 7. Open the hot tap. The operating light will glow on all Deluxe controllers. Measurement of the water flow at the

Página 29

TEMPERATURE CONTROL – DELUXE 35 Turning Off Bath Fill Mode During Its Operation The bath fill operation can be interrupted by pressing the BATH FILL b

Página 30

TEMPERATURE CONTROL – DELUXE 36 Notes on the Bath Fill mode: The Bath Fill mode can be set and turned on at any of the Deluxe controllers. The Del

Página 31 - BATH FILL button to finish”

TEMPERATURE CONTROL – DELUXE 37 Opening a Second Hot Water Tap During Bath Fill Operation The bath fill water volume is measured as the water flows

Página 32

TEMPERATURE CONTROL – DELUXE 38 Operation of the Bath Fill mode whilst a Deluxe Controller is ACTIVE It is recommended the Bath Fill mode be set and o

Página 33

39 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending to any condition or fault, which is not

Página 34 - 8. Close the hot tap

4 ABOUT YOUR WATER HEATER MODEL TYPE The Rheem® electronic continuous flow gas water heater model you have chosen is for outdoor installation only.

Página 35

SAVE A SERVICE CALL 40 GAS BOOSTER OPERATING TOO FREQUENTLY If the water heater is installed as a gas booster water heater to a solar preheat water he

Página 36

SAVE A SERVICE CALL 41 CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL During the heating cycle, it is not unusual to see water vapour clouds steaming

Página 37

42 INSTALLATION – WATER HEATER THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the wat

Página 38

INSTALLATION – WATER HEATER 43 As a guide the following requirements extracted from the Australian Gas Installations Standard AS 5601, must

Página 39 - SAVE A SERVICE CALL

INSTALLATION – WATER HEATER 44 MAINS WATER SUPPLY Where the mains water supply pressure exceeds that shown in the table below, an approv

Página 40

INSTALLATION – WATER HEATER 45 HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and w

Página 41 - HIGH GAS BILLS

INSTALLATION – WATER HEATER 46 Where a temperature limiting device is installed adjacent to the gas booster water heater, the cold water line to the t

Página 42 - INSTALLATION – WATER HEATER

INSTALLATION – WATER HEATER 47 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A Rheem continuous flow water heater cannot be installed as part of a circu

Página 43 - FROST PROTECTION

INSTALLATION – WATER HEATER 48 WATER TEMPERATURE DIAGRAMS 871 Series - Kitchen and Bathroom Controllers 875 Series – Kitchen and Bathroom Cont

Página 44 - MAINS WATER SUPPLY

INSTALLATION – WATER HEATER 49 DIMENSIONS AND TECHNICAL DATA Model 871 018 875 018 871 020 - 871 022 875 022 871 024 875 024 871 026 875 026 R

Página 45 - HOT WATER DELIVERY

ABOUT YOUR WATER HEATER 5 MAINS PRESSURE The water heater is designed for direct connection to the mains water supply. If the mains supply pressure in

Página 46

INSTALLATION – WATER HEATER 50 DIMENSIONS – STANDARD CONTROLLERS Kitchen Controller (Standard) Bathroom Controller (Standard)

Página 47 - REDUCING HEAT LOSSES

INSTALLATION – WATER HEATER 51 DIMENSIONS – DELUXE CONTROLLERS U UPSet Bath Fill Water Volumeand TemperatureBathWaterVolumeBathFillTempBath Fill1.

Página 48

INSTALLATION – WATER HEATER 52 TYPICAL INSTALLATION – OUTDOOR LOCATION 871, 875, 241, 245 SERIES CONTINUOUS FLOW GAS WATER HEATERTYPICAL INSTALLATIO

Página 49

INSTALLATION – WATER HEATER 53 TYPICAL INSTALLATION – GAS BOOSTER FOR OPEN CIRCUIT SOLAR LOLINE Typical Installation - Solar In-Line Gas BoosterSolar

Página 50

INSTALLATION – WATER HEATER 54 TYPICAL INSTALLATION – GAS BOOSTER FOR OPEN CIRCUIT SOLAR HILINE TYPICAL INSTALLATIONSOLAR THERMOSIPHON WITH IN-SERIES

Página 51

55 CONNECTIONS – PLUMBING CONNECTION SIZES Model 871 018 875 018 871 020 - 871 022 875 022 871 024 875 024 871 026 875 026 Hot water connection R½/1

Página 52 - TYPICAL INSTALLATION

CONNECTIONS – PLUMBING 56 PIPE SIZES The pipe sizing for hot water supply systems should be carried out by persons competent to do so, choosing the m

Página 53 - Typical Installation

57 CONNECTIONS – ELECTRICAL All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the Wiring Rul

Página 54

58 INSTALLATION – CONTROLLERS CONTROLLERS The Rheem 871 and 875 series can be installed with Rheem controllers to enable the user to control the tem

Página 55 - CONNECTIONS – PLUMBING

INSTALLATION – CONTROLLERS 59 Location – The controllers must be installed in dry, shaded and clean locations. Do not install the controllers: Near

Página 56 - GAS INLET

ABOUT YOUR WATER HEATER 6 WARNING This water heater is only intended to be operated by persons who have the experience or the knowledge and the capab

Página 57 - CONNECTIONS – ELECTRICAL

INSTALLATION – CONTROLLERS 60 Wiring installation: 1. Penetrate the wall with a 30-35 mm hole at the controller location. 2. Install the Kitchen con

Página 58 - INSTALLATION – CONTROLLERS

INSTALLATION – CONTROLLERS 61 If it is necessary to have an exposed wiring installation, follow this procedure omitting Steps 1 and 4, and make an ope

Página 59 - 2/08 REV-AD

INSTALLATION – CONTROLLERS 62 BATHROOM1 AND BATHROOM2 CONTROLLERS If only one Bathroom controller is to be installed, the standard Bathroom1 Controlle

Página 60

INSTALLATION – CONTROLLERS 63 Wiring installation: 1. Penetrate the wall with a 30-35 mm hole at the controller location. 2. Install the supplied ca

Página 61 - Exposed Cable

INSTALLATION – CONTROLLERS 64 CONNECTING THE CONTROLLER(S) TO THE WATER HEATER To connect the controller(s) to the water heater: 1. Ensure the electr

Página 62 - SK6370-1 A3

65 COMMISSIONING All water heaters are tested and adjusted before dispatch from the factory, however further adjustments may become necessary becaus

Página 63

COMMISSIONING 66 Gas Inlet Test Point Pressure To check the gas inlet pressure: 1. Close any hot taps and ensure the burners are not operating.

Página 64

COMMISSIONING 67 BURNER GAS PRESSURE It is necessary to check the burner gas pressure at both the minimum and maximum operational settings. To check a

Página 65 - COMMISSIONING

COMMISSIONING 68 Notes: If the burners extinguish and / or an error code starts to flash on the LED display:  release the MIN and adjuster buttons

Página 66 -  Connect the manometer

COMMISSIONING 69 PRESET OUTLET TEMPERATURE The factory preset outlet temperature of the water heater is: 871 series (pre 2007 manufacture date) 50°

Página 67

ABOUT YOUR WATER HEATER 7 TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater: Turn off the controllers(s) (if fitted) by p

Página 68

COMMISSIONING 70 TO CHECK OR ADJUST THE PRESET OUTLET TEMPERATURE The temperature settings will be displayed on the LED display. The preset temperatur

Página 69 - PRESET OUTLET TEMPERATURE

COMMISSIONING 71 TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater on completion of the installation, such as on a building

Página 70

72 DRAINING THE WATER HEATER To drain the water heater: Turn off the water heater (refer to “Turn Off The Water Heater” on page 71). Open a hot

Página 71 - TO TURN OFF THE WATER HEATER

73 This page is intentionally blank.

Página 72 - WATER SUPPLIES

74 This page is intentionally blank.

Página 73

75 RHEEM ELECTRONIC CONTINUOUS FLOW GAS WATER HEATER WARRANTY – AUSTRALIA ONLY WARRANTY CONDITIONS 1. This warranty is applicable only to wa

Página 74

RHEEM ELECTRONIC CONTINUOUS FLOW GAS WATER HEATER WARRANTY – AUSTRALIA ONLY Revision Date: 2008 October 31-76381-00  122133A 76 WARRANTY Rheem*

Página 75 - WARRANTY – AUSTRALIA ONLY

ABOUT YOUR WATER HEATER 8 HOW LONG WILL THE WATER HEATER LAST? There are a number of factors that will affect the length of service the

Página 76

9 TEMPERATURE CONTROL CONTROLLERS The Rheem 871 and 875 series can be installed with Rheem controllers to enable the user to control the temperature

Comentários a estes Manuais